RX Roof and Gutter Deicing Cables (Residential)
Danfoss RX Cables provide the protection needed to prevent build-up from damaging buildings, roofs, and gutters. Danfoss RX constant watt cables ensure maximum energy efficiency and are designed for use with metal or asphalt roofing.
- Constant watt cables
- Professional grade cable and AC plug
- 100% aluminum foil screen
- Electrical shock resistant
- High grade heating element
- Durable materials provide excellent moisture, corrosion and impact protection
- Tough UV-rated cable will withstand harshest conditions
- Plug directly into power receptacle
- Shingle Clips and Cable Spacers Included
Characteristics:
- Cable Length: 120 ft
- Watts: 535 total (5W/ft.)
- Amps: 4.5
- Warranty: 2 yrs
Cable Length Tables| Eave Overhang | Loop Height = Overhang + 6
| Roof Multiplier
|
12"
| 18"
| 1.9
|
24"
| 30"
| 2.7
|
36"
| 42"
| 3.6
|
48"
| 54"
| 4.6
|
| Section | Calculation | Cable Length (ft) |
| 1. Roof | Length x Multiplier |
|
| 2. Dormers | Number of x (sum up, over and down) |
|
| 3. Valleys | Number of x 6 ft |
|
| 4. Gutters* | Length x 1 ft |
|
| 5. Downspouts | Number of x (2 x height) |
|
|
| Total: |
*For
gutters more than 4” wide, make two traces of RX cable in the